STUDY OBJECTIVES AND METHODS
The purpose of this study was to compare the clinical/radiographic outcomes and the rate of disease resolution of the adjunctive use of electrolysis (GS) or hydrogen peroxide (HP) for mechanical decontamination in the reconstructive treatment of peri-implantitis-related intrabony defects. A multicenter randomized clinical trial was designed to compare the effectiveness and safety of two strategies for the surface decontamination of crater-like and circumferential intrabony defects subjected to reconstructive therapy. Clinical evaluation was made at baseline (T0), 6 months (T1) and 12 months (T2), while radiographic assessment was carried out at T0 and T2. Disease resolution was the primary outcome. Supportive therapy was administered following surgical treatment. Simple and multiple generalized estimating equations (GEE) models were applied to compare the outcomes achieved and to explore potential confounders. Post hoc power calculation was performed to validate the statistical power of the findings.
RESULTS
• Overall, 58 patients completed the study.
• All the clinical parameters/indices, namely probing pocket depth, modified sulcular bleeding index, suppuration grading index, and width of keratinized mucosa, showed a significant reduction (p < 0.001) from T0 to T2 in both tested groups.
• Mucosal recession increased (p < 0.001) from T0 to T2. Marginal bone level and radiographic defect angle increased (p < 0.001) from T0 to T2.
• The disease resolution rate was 87.5% for the GS group and 64.5% for the HP group at T2 (p = 0.08).
• No major postoperative complications were reported.
CONCLUSIONS
Both tested surface decontamination methods are effective in resolving peri-implantitis, in gaining radiographic marginal bone levels, and in enhancing clinical peri-implant conditions in the surgical reconstructive therapy
Adapted from A Monje et al., Clin Implant Dent Relat Res. 2025 Aug;27(4):e70075, for more info about this publication, click HERE.
This review is part of the Straumann "Scientific Highlights Newsletter 5/25".
More studies:
- Marginal Bone Level Changes in Full-Arch Rehabilitation: Digital Versus Analog Protocols-A 5-Year Retrospective Study
- Enamel matrix derivative in the prevention and treatment of medication-related osteonecrosis of the jaws in rats
- Effect of time and local factors on the stability of hydrophilic self-tapping tissue-level implants: 1-year prospective study
- Application of metallic guides and reverse scanning for full-mouth rehabilitation using implant-supported prostheses: A case report
- Evaluation of implant primary stability using different drilling protocols: an in vitro study
- The Future of Dental Implants: A Narrative Review of Trends, Technologies, and Patient Considerations