Section cuts

See for yourself and take a critical look at what characterizes a Medentika® Original

What does precision in detail mean?

Quality is demonstrated most clearly in a direct comparison – and we love transparency. For this reason we have prepared section cuts of our abutments and also those of the original manufacturer. The illustration reveals every single design and manufacturing feature. With these photographs we want to show you that we do not simply copy, but refine, whenever possible and appropriate.

The images below show the original implants. On the left with the fitted Medentika® abutment and on the right with the abutment of the respective original manufacturer. 

C-Series
compatible with Altatec® / Camlog® Screw-Line – Root-Line 2®

MEDENTiKA ABUTMENT C 9000 *

ALTATEC® CAMLOG SCREW-LINE - ROOT-LINE 2 **

1 Gap dimensions on the preliminary tube segment are practically identical to the original.
2 Vertical transmission of the tube segments is practically identical to the original.

CX-Series

compatible with Medentis Medical® / ICX®

MEDENTiKA ABUTMENT CX 1200 *

MEDENTIS MEDICAL® ICX **

1 High precisely manufactured conical section with respect to full-surface contact in the vertical extension. 
2 Emergence profile takes the physiology of the gingiva into account. 
3 Reduced gap dimensions on the preliminary tube ensure solid absorption of the horizontal forces exerted on the abutment.

E-Series

compatible with Nobel Biocare / NobelReplace® Tapered 

MEDENTiKA ABUTMENT E 100-1 *

NOBEL BIOCARE® NOBELREPLACE® TAPERED **

1 Reduced gap dimensions (see horizontal section below) on the preliminary cylindrical segments ensure reduced relative movements between the implant and abutment. This reduces the stress on the abutment screw and "micro-pump effect" of the system.

MEDENTiKA ABUTMENT E 100-1 *

NOBEL BIOCARE® NOBELREPLACE® TAPERED **

1 Reduced gap dimensions on the preliminary cylindrical segments ensure less relative movement between the implant and abutment. This reduces the stress on the abutment screw and "micro-pump effect" of the system.

EV-Series

compatible with DENTSPLY SIRONA / ASTRA TECH OsseoSpeed® EV 

MEDENTiKA ABUTMENT EV 110 *

DENTSPLY SIRONA ASTRA TECH OSSEOSPEED® EV **

1 Very precise conical fit with deep transmission in the conical section.

F-Series

compatible with Nobel Biocare® / NobelActive® / NobelReplace® Conical 

MEDENTiKA ABUTMENT F 100 *

NOBEL BIOCARE® NOBELACTIVE®/NOBELREPLACE® CONICAL **

1 A precisely manufactured conical section ensures full contact on the implant cone. A hex in the implant with the smallest possible gap dimensions ensures minimum rotation and axial stabilisation. A solid screw shank finally stabilizes the abutment with horizontal force application.

L-Series

compatible with Straumann Bone Level

MEDENTiKA® ABUTMENT L 110-3 *

STRAUMANN BONE LEVEL**

1 A highly precisely manufactured conical section provides full-surface contact. Reduced gap dimensions in the cylindricalelement ensure high axial stability with horizontal force application.  
2 Minimised gap dimensions provide axial stability and reduced relative movements between abutment and implant.

N-Series

compatible with Straumann Tissue Level

MEDENTiKA® ABUTMENT N 110 *

STRAUMANN TISSUE LEVEL **

1 The conical fit is very precise over the entire length.
2 + 3 Conical contact is also full surface and significantly deeper in the deep conical segment. This results in considerably deeper transmission of the exerted forces in the implant.

R-Series

compatible with Zimmer Dental® Tapered Screw-Vent® / MIS® SEVEN® Internal Hex / BioHorizons® Tapered Internal, Internal Plus, Tapered Tissue Level   

MEDENTiKA ABUTMENT R 100 *

ZIMMER DENTAL® TAPERED SCREW-VENT® **

1 Reduced gap dimensions in the hex for decreased rotation and increased axial stabilisation.
2 Shorter, more solid abutment screw for stabilisation of the abutment by horizontal force application. 

T-Series

compatible with DENTSPLY SIRONA  / XiVE® S

MEDENTiKA ABUTMENT T 105*

DENTSPLY SIRONA XIVE**

1 The gap in the first cylindrical segment is significantly reduced. This reduces the relative movement of the abutment to the implant and the force this exerts on the abutment screw.
2 The gap in the second segment is also reduced and ensures much deeper transmission. Deepest possible transmission of the forces ensures higher axial stabilisation of the abutment in the implant.

* All Medentika® abutments are displayed with the original implant from the manufacturer.
** All original implants are shown with original abutments from the respective manufacturer.