STUDY OBJECTIVES AND METHODS
The purpose of this study was to evaluate changes in implant stability quotient values of hydrophilic tissue-level implants over time, and to investigate the influence of local factors on variations in these values.METHODS: Fifty tapered, self-tapping, tissue-level implants with a hydrophilic surface were placed and monitored for 12 months. Implant stability quotient values were recorded at the time of insertion (T0) and monthly thereafter for 12 months. All implants were restored with screw-retained restorations 2 months after placement. A repeated measures analysis of variance was used to evaluate the trends in implant stability quotient values over time. A multiple linear regression model was employed to determine the impact of various factors on changes in implant stability quotient values.
RESULTS
- Implant stability quotient values decreased from T0 to T1, although this reduction was not statistically significant (P = 0.28).
- The greatest decrease was observed in implants with initially high implant stability quotient values at T0 (P 0.05). Values increased significantly at each subsequent time point (P 0.001).
- A significant time effect was noted between immediate and delayed placement protocols (P 0.05), with immediate implants demonstrating lower initial implant stability quotient values but a steeper increase over time.
- Implants placed in the mandible and wider implants in molar sites showed higher implant stability quotient values compared to those placed in the maxilla and narrower implants (mandible vs maxilla P 0.05; wide molar vs regular premolar P 0.05).
- Insertion torque was positively correlated with implant stability quotient values at T0 (P 0.001).
CONCLUSIONS
The lowest implant stability quotient value was recorded 1 month after implant placement, and then increased consistently throughout the study period without reaching a plateau. Implants placed immediately showed a steeper improvement in implant stability quotient values.
Adapted from P Carosi et al., Int J Oral Implantol (Berl). 2025 Sep 8;18(3):225-240, for more info about this publication, click HERE.
This review is part of the Straumann "Scientific Highlights Newsletter 5/25".
More studies:
- Marginal Bone Level Changes in Full-Arch Rehabilitation: Digital Versus Analog Protocols-A 5-Year Retrospective Study
- Three-Dimensional Objective Evaluation of the Changes in the Alveolar Ridge Before and After Horizontal Bone Augmentation Along with Implant Placement Using Intraoral Digital Scanning: A Prospective Study
- Enamel matrix derivative in the prevention and treatment of medication-related osteonecrosis of the jaws in rats
- Application of metallic guides and reverse scanning for full-mouth rehabilitation using implant-supported prostheses: A case report
- Evaluation of implant primary stability using different drilling protocols: an in vitro study
- Surface Decontamination on the Reconstructive Therapy of Peri-Implantitis: A Multicenter Randomized Clinical Trial
- The Future of Dental Implants: A Narrative Review of Trends, Technologies, and Patient Considerations