Straumann® BLX

Confidence beyond Immediacy.

Straumann® BLX, the winning combination of innovative design and surface technology with high-performance material designed for predictable results you can trust.

  • Dynamic Bone Management

    The intelligent implant concept allows for Straumann Dynamic Bone Management and is designed for immediate protocols in all bone types.

  • Esthetic Ease Concept

    Simplified but versatile portfolio, featuring one connection and under-contoured prosthetics to deliver esthetics with ease.

  • Beyond Immediacy

    Designed for immediacy, and also suitable for all other treatment protocols – ranging from immediate to conventional placement and loading – to suit the dentist’s preference.

  • Real Confidence

    Swiss precision and quality with Roxolid® material and SLActive® surface - technologies backed by long-term scientific evidence.

How can we help you?

Contact us

Data usage agreement*

Read our privacy policy.

Downloads

Documents

No resources found.
See all resources...

Videos & Animations

Straumann® BLX Trailer

BLX Product Animation
V0137-en 13.02.2019 MP4, 218 MB

BLX Drilling Protocol

BLX Product Animation
V0135-en 18.12.2018 MP4, 804 MB

BLX Product Teaser

BLX Product Animation
V0138-en 18.12.2018 MP4, 215 MB

60 Sec Eirik Salvesen Testimonial BLX

BLX Testimonial
V0175-EN 28.01.2019 MP4, 82 MB

BLX - Behind the Scene Video

Facts and Figures behind the Project
V0221-EN 15.02.2019 MP4, 515 MB

BLX Image Teaser Anna and the Lion

BLX Image Movie Teaser
V0222-EN 27.02.2019 MP4, 44 MB

BLX Immediate placement and provisional loading

BLX Indication Animation
V0167-EN 15.02.2019 MP4, 518 MB

BLX Prosthetics Consistent Emergence Profile

BLX Prosthetics Animation
V0161-EN 15.02.2019 MP4, 277 MB

BLX Prosthetics RB/WB RB Connection

BLX Prosthetics Animation
V0163-EN 15.02.2019 MP4, 304 MB

BLX Prosthetics TorcFit Connection

BLX Prosthetics Animation
V0162-EN 15.02.2019 MP4, 266 MB

BLX Surgical Cassette Features instruments

BLX Product Animation
V0134-en 18.12.2018 MP4, 374 MB
See all resources...

Scientific evidence

No resources found.

View selected scientific literature about Straumann® Bone Level and Bone Level Tapered implants.

Catalogs

International Course Calendar 2019

More than education
490.150/en/C/02 02/19 15.02.2019 PDF, 9 MB Download

DSO Global Courses 2019

Dental Service Organisation
490.483/en/A/01 01/19 23.01.2019 PDF, 15 MB Download

Product Catalog 2018/2019

Straumann International Edition
452.200/en/C/00 07/18 08.08.2018 PDF, 13 MB Download
See all resources...

References

1 Moraschini V, et al. Immediate versus conventional loaded single implants in the posterior mandible: a meta-analysis of randomized controlled trials. Int J Oral Maxillofac Surg 2016 Jan;45(1):85-92. Literature Review, full list available.
2 Ioannidis A, Gallucci GO, Jung RE, Borzangy S, Hämmerle CH, Benic GI. Titanium-zirconium narrow-diameter versus titanium regulardiameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. J Clin Periodontol. 2015 Nov;42(11):1060-70. doi: 10.1111/jcpe.12468. Epub 2015 Nov 14.
3 Al-Nawas B, Domagala P, Fragola G, Freiberger P, OrtizVigón A, Rousseau P, Tondela J. A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy. J Oral Implantol. 2015 Aug;41(4):e118-25. doi: 10.1563/AAID-JOI-D-13-00149. Epub 2014 Mar 25.
4 Altuna P, Lucas-Taulé E, Gargallo-Albiol J, Figueras-Álvarez O, Hernández-Alfaro F, Nart J. Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2016 Jul;45(7):842-50. doi: 10.1016/j.ijom.2016.01.004. Epub 2016 Feb 3.
5 Lang NP, Salvi GE, Huynh-Ba G, Ivanovski S, Donos N, Bosshardt DD. Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans. Clin Oral Implants Res. 2011 Apr;22(4):349-56. doi:10.1111/j.1600-0501.2011.02172.x
6 Oates TW, Valderrama P, Bischof M, Nedir R, Jones A, Simpson J, Toutenburg H, Cochran DL. Enhanced implant stability with a chemically modified SLA surface: a randomized pilot study. Int J Oral Maxillofac Implants. 2007 Sep-Oct;22(5):755-60
7 Nicolau P, Guerra F, Reis R, Krafft T, Benz K , Jackowski J. 10-year outcomes with immediate and early-loaded implants with a chemically modified SLA surface, Quintessence Int. (article in press).
8 Nelson, K., Stricker, A., Raguse, J.-D. Nahles, S. (2016), Rehabilitation of irradiated patients with chemically modified and conventional SLA implants: a clinical clarification. J Oral Rehabil, 43: 871–872. doi:10.1111/joor.12434.
9 Heberer S, Kilic S, Hossamo J, Raguse J-D, Nelson K. Rehabilitation of irradiated patients with modified and conventional sandblasted, acid-etched implants: preliminary results of a split-mouth study. Clin. Oral Impl. Res. 22, 2011; 546–551.
10 Cabrera-Domínguez J, Castellanos-Cosano L, Torres-Lagares D, Machuca-Portillo G. A Prospective Case-Control Clinical Study of Titanium-Zirconium Alloy Implants with a Hydrophilic Surface in Patients with Type 2 Diabetes Mellitus. Int J Oral Maxillofac Implants. 2017 Sep/Oct;32(5):1135-1144. doi: 10.11607/jomi.5577;
11  Cabrera-Domínguez J. A prospective, two-year clinical trial of titanium-zirconium alloy implants (Roxolid® Straumann®) with hydrophilic surface (SLActive®) in patients with Type 2 Diabetes Mellitus. presented during 26th Annual Scientific Meeting of the European Association of Osseointegration – 5-7 Oct 2017, Madrid, Spain
12 Kuchler U, Chappuis V, Bornstein mm, Siewczyk M, Gruber R, Maestre L, Buser D. Development of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation – results of a prospective study with 109 implants. Clin. Oral Impl. Res. 28, 2017, 109–115
13 Schwarz, F., et al., Bone regeneration in dehiscence-type defects at chemically modified (SLActive®) and conventional SLA® titanium implants: a pilot study in dogs. J Clin.Periodontol. 34.1 (2007): 78–86
14 Schwarz, F., et al., Bone regeneration in dehiscence-type defectsat non-submerged and submerged chemically modified (SLActive®) and conventional SLA titanium implants: an immunohistochemical study in dogs. J Clin.Periodontol. 35.1 (2008): 64–75.
15 El Chaar E, Zhang L, Zhou Y, et al. (Superior) osseointegration of superhydrophilic implants placed in defect grafted bones. Int J Oral Maxillofac Implants 2018. (article in press).